OFFLINE
Awaiting data
Security intelligence
MinorCritical vulnerability

CVE-2026-124850 (CVSS 7.3)

NVD · officialPublished Nov 9, 2026Risk 23/100

A SQL injection vulnerability exists in a database migration script in flowintel. The migration process reads stored connector identifier values from the database and interpolates them directly into SQL statements without parameterization. An attacker who has previously written a malicious identifier value into the affected tables can cause arbitrary SQL execution when the migration is subsequently run during an application upgrade. - Requires prior write access to the database to plant a malicious identifier value - Triggered automatically during a migration or upgrade operation - Can result in unauthorized data disclosure, modification, or deletion Affected versions: flowintel prior to 4.0.0

CVSS
7.3
AV:LocalAC:HighPR:LowUI:None

This record is attributed to NVD. Exploitation status and remediation guidance are kept separate from the vulnerability's technical severity.

Open primary source